Search Options

Results per page
Sort
Preferred Languages
Advance

Results 1 - 10 of 17 for SIGILL (0.23 sec)

  1. src/internal/cpu/cpu_arm64_hwcap.go

    	ARM64.HasCPUID = isSet(HWCap, hwcap_CPUID)
    	ARM64.HasSHA512 = isSet(HWCap, hwcap_SHA512)
    
    	// The Samsung S9+ kernel reports support for atomics, but not all cores
    	// actually support them, resulting in SIGILL. See issue #28431.
    	// TODO(elias.naur): Only disable the optimization on bad chipsets on android.
    	ARM64.HasATOMICS = isSet(HWCap, hwcap_ATOMICS) && os != "android"
    
    Registered: Wed Jun 12 16:32:35 UTC 2024
    - Last Modified: Wed May 22 21:17:41 UTC 2024
    - 2.4K bytes
    - Viewed (0)
  2. src/runtime/defs_netbsd.go

    	MADV_FREE     = C.MADV_FREE
    
    	SA_SIGINFO = C.SA_SIGINFO
    	SA_RESTART = C.SA_RESTART
    	SA_ONSTACK = C.SA_ONSTACK
    
    	SIGHUP    = C.SIGHUP
    	SIGINT    = C.SIGINT
    	SIGQUIT   = C.SIGQUIT
    	SIGILL    = C.SIGILL
    	SIGTRAP   = C.SIGTRAP
    	SIGABRT   = C.SIGABRT
    	SIGEMT    = C.SIGEMT
    	SIGFPE    = C.SIGFPE
    	SIGKILL   = C.SIGKILL
    	SIGBUS    = C.SIGBUS
    	SIGSEGV   = C.SIGSEGV
    	SIGSYS    = C.SIGSYS
    	SIGPIPE   = C.SIGPIPE
    Registered: Wed Jun 12 16:32:35 UTC 2024
    - Last Modified: Fri Apr 12 21:17:22 UTC 2024
    - 2.9K bytes
    - Viewed (0)
  3. src/runtime/defs_dragonfly.go

    	MADV_FREE     = C.MADV_FREE
    
    	SA_SIGINFO = C.SA_SIGINFO
    	SA_RESTART = C.SA_RESTART
    	SA_ONSTACK = C.SA_ONSTACK
    
    	SIGHUP    = C.SIGHUP
    	SIGINT    = C.SIGINT
    	SIGQUIT   = C.SIGQUIT
    	SIGILL    = C.SIGILL
    	SIGTRAP   = C.SIGTRAP
    	SIGABRT   = C.SIGABRT
    	SIGEMT    = C.SIGEMT
    	SIGFPE    = C.SIGFPE
    	SIGKILL   = C.SIGKILL
    	SIGBUS    = C.SIGBUS
    	SIGSEGV   = C.SIGSEGV
    	SIGSYS    = C.SIGSYS
    	SIGPIPE   = C.SIGPIPE
    Registered: Wed Jun 12 16:32:35 UTC 2024
    - Last Modified: Fri Apr 12 21:17:22 UTC 2024
    - 2.9K bytes
    - Viewed (0)
  4. src/runtime/defs_darwin.go

    	SA_RESTART   = C.SA_RESTART
    	SA_ONSTACK   = C.SA_ONSTACK
    	SA_USERTRAMP = C.SA_USERTRAMP
    	SA_64REGSET  = C.SA_64REGSET
    
    	SIGHUP    = C.SIGHUP
    	SIGINT    = C.SIGINT
    	SIGQUIT   = C.SIGQUIT
    	SIGILL    = C.SIGILL
    	SIGTRAP   = C.SIGTRAP
    	SIGABRT   = C.SIGABRT
    	SIGEMT    = C.SIGEMT
    	SIGFPE    = C.SIGFPE
    	SIGKILL   = C.SIGKILL
    	SIGBUS    = C.SIGBUS
    	SIGSEGV   = C.SIGSEGV
    	SIGSYS    = C.SIGSYS
    	SIGPIPE   = C.SIGPIPE
    Registered: Wed Jun 12 16:32:35 UTC 2024
    - Last Modified: Fri Apr 12 21:17:22 UTC 2024
    - 4.3K bytes
    - Viewed (0)
  5. src/runtime/defs_freebsd.go

    	UMTX_OP_WAKE              = C.UMTX_OP_WAKE
    	UMTX_OP_WAKE_PRIVATE      = C.UMTX_OP_WAKE_PRIVATE
    
    	SIGHUP    = C.SIGHUP
    	SIGINT    = C.SIGINT
    	SIGQUIT   = C.SIGQUIT
    	SIGILL    = C.SIGILL
    	SIGTRAP   = C.SIGTRAP
    	SIGABRT   = C.SIGABRT
    	SIGEMT    = C.SIGEMT
    	SIGFPE    = C.SIGFPE
    	SIGKILL   = C.SIGKILL
    	SIGBUS    = C.SIGBUS
    	SIGSEGV   = C.SIGSEGV
    	SIGSYS    = C.SIGSYS
    	SIGPIPE   = C.SIGPIPE
    Registered: Wed Jun 12 16:32:35 UTC 2024
    - Last Modified: Fri Apr 12 21:17:22 UTC 2024
    - 4.1K bytes
    - Viewed (0)
  6. src/vendor/golang.org/x/sys/cpu/cpu_linux_arm64.go

    		// trap into the kernel and then return back to userspace.
    		//
    		// But on older kernels, such as Linux 4.4.180 as used on many Synology
    		// devices, calling readARM64Registers (specifically getisar0) will
    		// cause a SIGILL and we'll die. So for older kernels, parse /proc/cpuinfo
    		// instead.
    		//
    		// See golang/go#57336.
    		if linuxKernelCanEmulateCPUID() {
    			readARM64Registers()
    		} else {
    			readLinuxProcCPUInfo()
    		}
    Registered: Wed Jun 12 16:32:35 UTC 2024
    - Last Modified: Wed May 08 16:12:58 UTC 2024
    - 3.4K bytes
    - Viewed (0)
  7. src/os/signal/doc.go

    with a stack dump by pressing ^\.
    
    # Default behavior of signals in Go programs
    
    By default, a synchronous signal is converted into a run-time panic. A
    SIGHUP, SIGINT, or SIGTERM signal causes the program to exit. A
    SIGQUIT, SIGILL, SIGTRAP, SIGABRT, SIGSTKFLT, SIGEMT, or SIGSYS signal
    causes the program to exit with a stack dump. A SIGTSTP, SIGTTIN, or
    SIGTTOU signal gets the system default behavior (these signals are
    Registered: Wed Jun 12 16:32:35 UTC 2024
    - Last Modified: Fri Jun 07 18:11:00 UTC 2024
    - 11K bytes
    - Viewed (0)
  8. src/syscall/syscall_wasip1.go

    }
    
    // A Signal is a number describing a process signal.
    // It implements the [os.Signal] interface.
    type Signal uint8
    
    const (
    	SIGNONE Signal = iota
    	SIGHUP
    	SIGINT
    	SIGQUIT
    	SIGILL
    	SIGTRAP
    	SIGABRT
    	SIGBUS
    	SIGFPE
    	SIGKILL
    	SIGUSR1
    	SIGSEGV
    	SIGUSR2
    	SIGPIPE
    	SIGALRM
    	SIGTERM
    	SIGCHLD
    	SIGCONT
    	SIGSTOP
    	SIGTSTP
    	SIGTTIN
    	SIGTTOU
    Registered: Wed Jun 12 16:32:35 UTC 2024
    - Last Modified: Mon Feb 26 21:03:59 UTC 2024
    - 9.4K bytes
    - Viewed (0)
  9. src/cmd/vendor/golang.org/x/sys/unix/zerrors_zos_s390x.go

    	EINTRNODATA        = Errno(1159)
    	ENOREUSE           = Errno(1160)
    	ENOMOVE            = Errno(1161)
    )
    
    // Signals
    const (
    	SIGHUP    = Signal(1)
    	SIGINT    = Signal(2)
    	SIGABRT   = Signal(3)
    	SIGILL    = Signal(4)
    	SIGPOLL   = Signal(5)
    	SIGURG    = Signal(6)
    	SIGSTOP   = Signal(7)
    	SIGFPE    = Signal(8)
    	SIGKILL   = Signal(9)
    	SIGBUS    = Signal(10)
    	SIGSEGV   = Signal(11)
    	SIGSYS    = Signal(12)
    Registered: Wed Jun 12 16:32:35 UTC 2024
    - Last Modified: Wed May 08 16:12:58 UTC 2024
    - 39.4K bytes
    - Viewed (0)
  10. src/cmd/vendor/golang.org/x/sys/unix/zerrors_linux_arm64.go

    }
    
    // Signal table
    var signalList = [...]struct {
    	num  syscall.Signal
    	name string
    	desc string
    }{
    	{1, "SIGHUP", "hangup"},
    	{2, "SIGINT", "interrupt"},
    	{3, "SIGQUIT", "quit"},
    	{4, "SIGILL", "illegal instruction"},
    	{5, "SIGTRAP", "trace/breakpoint trap"},
    	{6, "SIGABRT", "aborted"},
    	{7, "SIGBUS", "bus error"},
    	{8, "SIGFPE", "floating point exception"},
    	{9, "SIGKILL", "killed"},
    Registered: Wed Jun 12 16:32:35 UTC 2024
    - Last Modified: Tue Jun 04 16:19:04 UTC 2024
    - 34.2K bytes
    - Viewed (0)
Back to top