- Sort Score
- Result 10 results
- Languages All
Results 1 - 10 of 184 for exit2 (0.1 sec)
-
src/runtime/os_plan9.go
func minit() { if atomic.Load(&exiting) != 0 { exits(&emptystatus[0]) } // Mask all SSE floating-point exceptions // when running on the 64-bit kernel. setfpmasks() } // Called from dropm to undo the effect of an minit. func unminit() { } // Called from exitm, but not from drop, to undo the effect of thread-owned
Registered: Wed Jun 12 16:32:35 UTC 2024 - Last Modified: Fri May 17 15:41:45 UTC 2024 - 10.3K bytes - Viewed (0) -
src/os/exec/exec_test.go
t.Errorf("from exit 42 got exit %q, want %q", s, want) } } else { t.Fatalf("expected *exec.ExitError from exit 42; got %T: %v", err, err) } } func TestExitCode(t *testing.T) { t.Parallel() // Test that exit code are returned correctly cmd := helperCommand(t, "exit", "42") cmd.Run() want := 42 if runtime.GOOS == "plan9" { want = 1 }
Registered: Wed Jun 12 16:32:35 UTC 2024 - Last Modified: Fri Jun 07 20:13:53 UTC 2024 - 48.4K bytes - Viewed (0) -
pkg/test/framework/test.go
// }) // // Exits before T2a and T2b are run. // }) // }) // } // // In the example above, non-parallel parents T1 and T2 contain parallel children T1a, T1b, T2a, T2b. // // Since both T1 and T2 are non-parallel, they are run synchronously: T1 followed by T2. After T1 exits,
Registered: Fri Jun 14 15:00:06 UTC 2024 - Last Modified: Thu Jun 06 22:12:34 UTC 2024 - 10.3K bytes - Viewed (0) -
src/os/exec/exec.go
return e.ProcessState.String() } // Wait waits for the command to exit and waits for any copying to // stdin or copying from stdout or stderr to complete. // // The command must have been started by [Cmd.Start]. // // The returned error is nil if the command runs, has no problems // copying stdin, stdout, and stderr, and exits with a zero exit // status. //
Registered: Wed Jun 12 16:32:35 UTC 2024 - Last Modified: Fri Jun 07 20:13:53 UTC 2024 - 41.4K bytes - Viewed (0) -
src/os/signal/doc.go
program to simply exit by pressing ^C, and you can cause it to exit with a stack dump by pressing ^\. # Default behavior of signals in Go programs By default, a synchronous signal is converted into a run-time panic. A SIGHUP, SIGINT, or SIGTERM signal causes the program to exit. A SIGQUIT, SIGILL, SIGTRAP, SIGABRT, SIGSTKFLT, SIGEMT, or SIGSYS signal causes the program to exit with a stack dump. A SIGTSTP, SIGTTIN, or
Registered: Wed Jun 12 16:32:35 UTC 2024 - Last Modified: Fri Jun 07 18:11:00 UTC 2024 - 11K bytes - Viewed (0) -
src/cmd/link/internal/ld/main.go
usage() } if *FlagD && ctxt.UsesLibc() { Exitf("dynamic linking required on %s; -d flag cannot be used", buildcfg.GOOS) } isPowerOfTwo := func(n int64) bool { return n > 0 && n&(n-1) == 0 } if *FlagRound != -1 && (*FlagRound < 4096 || !isPowerOfTwo(*FlagRound)) { Exitf("invalid -R value 0x%x", *FlagRound) } checkStrictDups = *FlagStrictDups
Registered: Wed Jun 12 16:32:35 UTC 2024 - Last Modified: Fri May 17 16:59:50 UTC 2024 - 16.6K bytes - Viewed (0) -
pkg/test/framework/suite.go
"istio.io/istio/pkg/test/framework/resource" "istio.io/istio/pkg/test/prow" "istio.io/istio/pkg/test/scopes" "istio.io/istio/pkg/tracing" ) // test.Run uses 0, 1, 2 exit codes. Use different exit codes for our framework. const ( // Indicates a framework-level init error exitCodeInitError = -1 // Indicates an error due to the setup function supplied by the user exitCodeSetupError = -2 )
Registered: Fri Jun 14 15:00:06 UTC 2024 - Last Modified: Thu Jun 06 22:12:34 UTC 2024 - 17.2K bytes - Viewed (0) -
docs/bucket/replication/setup_ilm_expiry_replication.sh
echo "BUG: ILM expiry rules prefix not replicated to 'siteb'" exit 1 fi if [ "${ntagName1}" != "ntag1" ] || [ "${ntagVal1}" != "nval1" ] || [ "${ntagName2}" != "ntag2" ] || [ "${ntagVal2}" != "nval2" ]; then echo "BUG: ILM expiry rules tags not replicated to 'siteb'" exit 1 fi if [ "${st}" != "Disabled" ]; then echo "BUG: ILM expiry rules status not replicated to 'siteb'" exit 1 fi
Registered: Sun Jun 16 00:44:34 UTC 2024 - Last Modified: Sat May 18 18:19:01 UTC 2024 - 12.8K bytes - Viewed (0) -
src/runtime/panic.go
// Just print a stack trace and exit. gp.m.dying = 2 print("panic during panic\n") return false case 2: // This is a genuine bug in the runtime, we couldn't even // print the stack trace successfully. gp.m.dying = 3 print("stack trace unavailable\n") exit(4) fallthrough default: // Can't even print! Just exit. exit(5) return false // Need to return something.
Registered: Wed Jun 12 16:32:35 UTC 2024 - Last Modified: Wed May 29 17:58:53 UTC 2024 - 43.8K bytes - Viewed (0) -
tensorflow/compiler/jit/shape_inference_test.cc
auto loop_cond = ops::LoopCond(scope.WithOpName("while/LoopCond"), less); auto switch_node = ops::Switch(scope.WithOpName("while/Switch"), merge.output, loop_cond); auto exit = ops::internal::Exit(scope.WithOpName("while/Exit"), switch_node.output_false); auto identity = ops::Identity(scope.WithOpName("while/Identity"), switch_node.output_true);
Registered: Sun Jun 16 05:45:23 UTC 2024 - Last Modified: Fri May 31 00:41:19 UTC 2024 - 10.3K bytes - Viewed (0)