- Sort Score
- Result 10 results
- Languages All
Results 91 - 100 of 123 for instructions (0.08 sec)
-
CHANGELOG/CHANGELOG-1.7.md
* Plugins * Introduces the ability to extend kubectl by adding third-party plugins. Developer preview, please refer to the documentation for instructions about how to use it. ([#37499](https://github.com/kubernetes/kubernetes/pull/37499), [@fabianofranz](https://github.com/fabianofranz))Registered: Fri Dec 26 09:05:12 UTC 2025 - Last Modified: Thu May 05 13:44:43 UTC 2022 - 308.7K bytes - Viewed (1) -
src/cmd/asm/internal/asm/line_test.go
{"VADDPD.RZ_SAE.SAE X0, X1, X2", `bad suffix combination`}, // BSWAP on 16-bit registers is undefined. See #29167, {"BSWAPW DX", `unrecognized instruction`}, {"BSWAPW R11", `unrecognized instruction`}, }) } func testBadInstParser(t *testing.T, goarch string, tests []badInstTest) { for i, test := range tests { arch, ctxt := setArch(goarch)Registered: Tue Dec 30 11:13:12 UTC 2025 - Last Modified: Tue Aug 29 07:48:38 UTC 2023 - 1.9K bytes - Viewed (0) -
src/cmd/asm/internal/asm/testdata/riscv64error.s
MOVWU X5, (X6) // ERROR "unsupported unsigned store" MOVF F0, F1, F2 // ERROR "illegal MOV instruction" MOVD F0, F1, F2 // ERROR "illegal MOV instruction" MOV X10, X11, X12 // ERROR "illegal MOV instruction" MOVW X10, X11, X12 // ERROR "illegal MOV instruction" RORI $64, X5, X6 // ERROR "immediate out of range 0 to 63" SLLI $64, X5, X6 // ERROR "immediate out of range 0 to 63"
Registered: Tue Dec 30 11:13:12 UTC 2025 - Last Modified: Wed Sep 24 13:21:53 UTC 2025 - 26.8K bytes - Viewed (0) -
src/cmd/asm/internal/asm/testdata/loong64.s
// Copyright 2022 The Go Authors. All rights reserved. // Use of this source code is governed by a BSD-style // license that can be found in the LICENSE file. #include "../../../../../runtime/textflag.h" // TODO: cover more instruction TEXT foo(SB),DUPOK|NOSPLIT,$0 JAL 1(PC) //CALL 1(PC) //00040054 JAL (R4) //CALL (R4) //8100004c // relocation in play so the assembled offset should be 0
Registered: Tue Dec 30 11:13:12 UTC 2025 - Last Modified: Wed Mar 22 18:50:59 UTC 2023 - 434 bytes - Viewed (0) -
CHANGELOG/CHANGELOG-1.16.md
- `http_404_request_duration_ms` (the amount of time the server took to respond in ms) Also includes percentile groupings. The directory for the default 404 handler includes instructions on how to enable prometheus for monitoring and setting alerts. ([#79106](https://github.com/kubernetes/kubernetes/pull/79106), [@vbannai](https://github.com/vbannai)) ### Instrumentation
Registered: Fri Dec 26 09:05:12 UTC 2025 - Last Modified: Wed Oct 23 20:13:20 UTC 2024 - 345.2K bytes - Viewed (0) -
docs/es/docs/deployment/docker.md
/// /// warning | Advertencia Asegúrate de **siempre** usar la **forma exec** de la instrucción `CMD`, como se explica a continuación. /// #### Usar `CMD` - Forma Exec { #use-cmd-exec-form } La instrucción Docker <a href="https://docs.docker.com/reference/dockerfile/#cmd" class="external-link" target="_blank">`CMD`</a> se puede escribir usando dos formas:Registered: Sun Dec 28 07:19:09 UTC 2025 - Last Modified: Tue Dec 16 16:33:45 UTC 2025 - 32K bytes - Viewed (0) -
lib/fips140/v1.0.0-c2097c7c.zip
to ppc64le. // Some changes were needed due to differences in // the Go opcodes and/or available instructions // between s390x and ppc64le. // 1. There were operand order differences in the // VSUBUQM, VSUBCUQ, and VSEL instructions. // 2. ppc64 does not have a multiply high and low // like s390x, so those were implemented using // macros to compute the equivalent values. // 3. The LVX, STVX instructions on ppc64 require // 16 byte alignment of the data. To avoid that // requirement, data is loaded...
Registered: Tue Dec 30 11:13:12 UTC 2025 - Last Modified: Thu Sep 25 19:53:19 UTC 2025 - 642.7K bytes - Viewed (0) -
src/cmd/asm/internal/arch/s390x.go
// Use of this source code is governed by a BSD-style // license that can be found in the LICENSE file. // This file encapsulates some of the odd characteristics of the // s390x instruction set, to minimize its interaction // with the core of the assembler. package arch import ( "cmd/internal/obj/s390x" ) func jumpS390x(word string) bool { switch word { case "BRC", "BC",
Registered: Tue Dec 30 11:13:12 UTC 2025 - Last Modified: Thu Oct 17 14:55:25 UTC 2019 - 1.2K bytes - Viewed (0) -
docs/en/docs/release-notes.md
* 📝 Update includes in `docs/ru/docs/tutorial/query-param-models.md`. PR [#12994](https://github.com/fastapi/fastapi/pull/12994) by [@alejsdev](https://github.com/alejsdev). * ✏️ Fix typo in README installation instructions. PR [#13011](https://github.com/fastapi/fastapi/pull/13011) by [@dave-hay](https://github.com/dave-hay).
Registered: Sun Dec 28 07:19:09 UTC 2025 - Last Modified: Sat Dec 27 19:06:15 UTC 2025 - 586.7K bytes - Viewed (0) -
docs/ja/llm-prompt.md
### Target language Translate to Japanese (日本語). Language code: ja. ### Grammar and tone 1) Use polite, instructional Japanese (です/ます調). 2) Keep the tone concise and technical (match existing Japanese FastAPI docs). ### Headings 1) Follow the existing Japanese style: short, descriptive headings (often noun phrases), e.g. 「チェック」. 2) Do not add a trailing period at the end of headings. ### Quotes
Registered: Sun Dec 28 07:19:09 UTC 2025 - Last Modified: Sat Dec 20 17:30:52 UTC 2025 - 1.3K bytes - Viewed (0)