Search Options

Results per page
Sort
Preferred Languages
Advance

Results 11 - 18 of 18 for SIGUSR2 (0.23 sec)

  1. src/cmd/vendor/golang.org/x/sys/unix/zerrors_linux_mips64.go

    	SIGSYS    = syscall.Signal(0xc)
    	SIGTSTP   = syscall.Signal(0x18)
    	SIGTTIN   = syscall.Signal(0x1a)
    	SIGTTOU   = syscall.Signal(0x1b)
    	SIGURG    = syscall.Signal(0x15)
    	SIGUSR1   = syscall.Signal(0x10)
    	SIGUSR2   = syscall.Signal(0x11)
    	SIGVTALRM = syscall.Signal(0x1c)
    	SIGWINCH  = syscall.Signal(0x14)
    	SIGXCPU   = syscall.Signal(0x1e)
    	SIGXFSZ   = syscall.Signal(0x1f)
    )
    
    // Error table
    Registered: Wed Jun 12 16:32:35 UTC 2024
    - Last Modified: Mon Jan 22 19:00:13 UTC 2024
    - 34.7K bytes
    - Viewed (0)
  2. src/cmd/vendor/golang.org/x/sys/unix/zerrors_linux_sparc64.go

    	SIGSYS    = syscall.Signal(0xc)
    	SIGTSTP   = syscall.Signal(0x12)
    	SIGTTIN   = syscall.Signal(0x15)
    	SIGTTOU   = syscall.Signal(0x16)
    	SIGURG    = syscall.Signal(0x10)
    	SIGUSR1   = syscall.Signal(0x1e)
    	SIGUSR2   = syscall.Signal(0x1f)
    	SIGVTALRM = syscall.Signal(0x1a)
    	SIGWINCH  = syscall.Signal(0x1c)
    	SIGXCPU   = syscall.Signal(0x18)
    	SIGXFSZ   = syscall.Signal(0x19)
    )
    
    // Error table
    Registered: Wed Jun 12 16:32:35 UTC 2024
    - Last Modified: Mon Jan 22 19:00:13 UTC 2024
    - 38.7K bytes
    - Viewed (0)
  3. src/cmd/vendor/golang.org/x/sys/unix/zerrors_linux_ppc64.go

    	SIGSYS    = syscall.Signal(0x1f)
    	SIGTSTP   = syscall.Signal(0x14)
    	SIGTTIN   = syscall.Signal(0x15)
    	SIGTTOU   = syscall.Signal(0x16)
    	SIGURG    = syscall.Signal(0x17)
    	SIGUSR1   = syscall.Signal(0xa)
    	SIGUSR2   = syscall.Signal(0xc)
    	SIGVTALRM = syscall.Signal(0x1a)
    	SIGWINCH  = syscall.Signal(0x1c)
    	SIGXCPU   = syscall.Signal(0x18)
    	SIGXFSZ   = syscall.Signal(0x19)
    )
    
    // Error table
    Registered: Wed Jun 12 16:32:35 UTC 2024
    - Last Modified: Mon Jan 22 19:00:13 UTC 2024
    - 36.9K bytes
    - Viewed (0)
  4. src/cmd/vendor/golang.org/x/sys/unix/zerrors_linux_ppc64le.go

    	SIGSYS    = syscall.Signal(0x1f)
    	SIGTSTP   = syscall.Signal(0x14)
    	SIGTTIN   = syscall.Signal(0x15)
    	SIGTTOU   = syscall.Signal(0x16)
    	SIGURG    = syscall.Signal(0x17)
    	SIGUSR1   = syscall.Signal(0xa)
    	SIGUSR2   = syscall.Signal(0xc)
    	SIGVTALRM = syscall.Signal(0x1a)
    	SIGWINCH  = syscall.Signal(0x1c)
    	SIGXCPU   = syscall.Signal(0x18)
    	SIGXFSZ   = syscall.Signal(0x19)
    )
    
    // Error table
    Registered: Wed Jun 12 16:32:35 UTC 2024
    - Last Modified: Mon Jan 22 19:00:13 UTC 2024
    - 36.9K bytes
    - Viewed (0)
  5. src/cmd/vendor/golang.org/x/sys/unix/zerrors_linux_s390x.go

    	SIGSYS    = syscall.Signal(0x1f)
    	SIGTSTP   = syscall.Signal(0x14)
    	SIGTTIN   = syscall.Signal(0x15)
    	SIGTTOU   = syscall.Signal(0x16)
    	SIGURG    = syscall.Signal(0x17)
    	SIGUSR1   = syscall.Signal(0xa)
    	SIGUSR2   = syscall.Signal(0xc)
    	SIGVTALRM = syscall.Signal(0x1a)
    	SIGWINCH  = syscall.Signal(0x1c)
    	SIGXCPU   = syscall.Signal(0x18)
    	SIGXFSZ   = syscall.Signal(0x19)
    )
    
    // Error table
    Registered: Wed Jun 12 16:32:35 UTC 2024
    - Last Modified: Mon Jan 22 19:00:13 UTC 2024
    - 36.7K bytes
    - Viewed (0)
  6. src/cmd/vendor/golang.org/x/sys/unix/zerrors_zos_s390x.go

    	SIGKILL   = Signal(9)
    	SIGBUS    = Signal(10)
    	SIGSEGV   = Signal(11)
    	SIGSYS    = Signal(12)
    	SIGPIPE   = Signal(13)
    	SIGALRM   = Signal(14)
    	SIGTERM   = Signal(15)
    	SIGUSR1   = Signal(16)
    	SIGUSR2   = Signal(17)
    	SIGABND   = Signal(18)
    	SIGCONT   = Signal(19)
    	SIGCHLD   = Signal(20)
    	SIGTTIN   = Signal(21)
    	SIGTTOU   = Signal(22)
    	SIGIO     = Signal(23)
    	SIGQUIT   = Signal(24)
    Registered: Wed Jun 12 16:32:35 UTC 2024
    - Last Modified: Wed May 08 16:12:58 UTC 2024
    - 39.4K bytes
    - Viewed (0)
  7. src/os/signal/doc.go

    SIGQUIT, SIGABRT, and SIGTERM. It also applies to the job control
    signals SIGTSTP, SIGTTIN, and SIGTTOU, in which case the system
    default behavior does not occur. It also applies to some signals that
    otherwise cause no action: SIGUSR1, SIGUSR2, SIGPIPE, SIGALRM,
    SIGCHLD, SIGCONT, SIGURG, SIGXCPU, SIGXFSZ, SIGVTALRM, SIGWINCH,
    SIGIO, SIGPWR, SIGINFO, SIGTHR, SIGWAITING, SIGLWP, SIGFREEZE,
    SIGTHAW, SIGLOST, SIGXRES, SIGJVM1, SIGJVM2, and any real time signals
    Registered: Wed Jun 12 16:32:35 UTC 2024
    - Last Modified: Fri Jun 07 18:11:00 UTC 2024
    - 11K bytes
    - Viewed (0)
  8. src/runtime/signal_unix.go

    // consequences. For example, SIGALRM is a bad choice because the
    // signal handler can't tell if it was caused by the real process
    // alarm or not (arguably this means the signal is broken, but I
    // digress). SIGUSR1 and SIGUSR2 are also bad because those are often
    // used in meaningful ways by applications.
    //
    // 4. We need to deal with platforms without real-time signals (like
    // macOS), so those are out.
    //
    Registered: Wed Jun 12 16:32:35 UTC 2024
    - Last Modified: Fri May 10 16:04:54 UTC 2024
    - 45K bytes
    - Viewed (0)
Back to top