- Sort Score
- Result 10 results
- Languages All
Results 51 - 60 of 244 for aligned2 (0.16 sec)
-
src/vendor/golang.org/x/net/route/sys_netbsd.go
ifanm := &wireFormat{extOff: sizeofIfAnnouncemsghdrNetBSD7, bodyOff: sizeofIfAnnouncemsghdrNetBSD7} ifanm.parse = ifanm.parseInterfaceAnnounceMessage // NetBSD 6 and above kernels require 64-bit aligned access to // routing facilities. return 8, map[int]*wireFormat{ syscall.RTM_ADD: rtm, syscall.RTM_DELETE: rtm, syscall.RTM_CHANGE: rtm, syscall.RTM_GET: rtm,
Registered: Wed Jun 12 16:32:35 UTC 2024 - Last Modified: Fri Aug 05 19:54:32 UTC 2022 - 2.2K bytes - Viewed (0) -
src/internal/trace/gc_test.go
for i, u := range util { if u.Time+int64(window) > util[len(util)-1].Time { break } mmu = math.Min(mmu, muInWindow(util[i:], u.Time+int64(window))) } } // Consider all left-aligned windows. update() // Reverse the trace. Slightly subtle because each MutatorUtil // is a *change*. rutil := make([]trace.MutatorUtil, len(util)) if util[len(util)-1].Util != 0 { panic("irreversible trace")
Registered: Wed Jun 12 16:32:35 UTC 2024 - Last Modified: Fri May 17 18:48:18 UTC 2024 - 5.3K bytes - Viewed (0) -
pkg/kubelet/cm/devicemanager/manager.go
if err != nil { return nil, err } if allocateRemainingFrom(preferred.Intersection(aligned)) { return allocated, nil } // Then fallback to allocate from the aligned set if no preferred list // is returned (or not enough devices are returned in that list). if allocateRemainingFrom(aligned) { return allocated, nil }
Registered: Sat Jun 15 01:39:40 UTC 2024 - Last Modified: Mon Apr 15 12:01:56 UTC 2024 - 43K bytes - Viewed (0) -
platforms/software/dependency-management/src/integTest/groovy/org/gradle/integtests/resolve/alignment/AlignmentIntegrationTest.groovy
if (it.getId().getGroup().startsWith("nebula")) { it.belongsTo("aligned-group:nebula:\${it.getId().getVersion()}") } if (it.getId().getGroup().startsWith("proto")) { it.belongsTo("aligned-group:proto:\${it.getId().getVersion()}") }
Registered: Wed Jun 12 18:38:38 UTC 2024 - Last Modified: Tue Oct 10 21:10:11 UTC 2023 - 59.6K bytes - Viewed (0) -
internal/bpool/bpool.go
// available in the pool. func (bp *BytePoolCap) Get() (b []byte) { if bp == nil { return nil } select { case b = <-bp.c: // reuse existing buffer default: // create new aligned buffer if bp.wcap > 0 { b = reedsolomon.AllocAligned(1, bp.wcap)[0][:bp.w] } else { b = reedsolomon.AllocAligned(1, bp.w)[0] } } return } // Put returns the given Buffer to the BytePool.
Registered: Sun Jun 16 00:44:34 UTC 2024 - Last Modified: Fri Apr 19 16:44:59 UTC 2024 - 2.6K bytes - Viewed (0) -
src/internal/bytealg/compare_mips64x.s
entry: ADDV R3, R10, R8 // R3 start of a, R8 end of a BEQ R3, R8, samebytes // length is 0 SRLV $4, R10 // R10 is number of chunks BEQ R0, R10, byte_loop // make sure both a and b are aligned. OR R3, R4, R11 AND $7, R11 BNE R0, R11, byte_loop chunk16_loop: BEQ R0, R10, byte_loop MOVV (R3), R6 MOVV (R4), R7 BNE R6, R7, byte_loop MOVV 8(R3), R13 MOVV 8(R4), R14 ADDV $16, R3
Registered: Wed Jun 12 16:32:35 UTC 2024 - Last Modified: Sat Nov 06 10:24:44 UTC 2021 - 1.7K bytes - Viewed (0) -
src/cmd/internal/obj/ppc64/doc.go
Starting with Go 1.12, Go asm supports the PCALIGN directive, which indicates that the next instruction should be aligned to the specified value. Currently 8 and 16 are the only supported values, and a maximum of 2 NOPs will be added to align the code. That means in the case where the code is aligned to 4 but PCALIGN $16 is at that location, the code will only be aligned to 8 to avoid adding 3 NOPs.
Registered: Wed Jun 12 16:32:35 UTC 2024 - Last Modified: Fri Apr 21 16:47:45 UTC 2023 - 11.3K bytes - Viewed (0) -
src/internal/goarch/goarch.go
// the compiler word, the link editor word, and the TOC save word. const MinFrameSize = _MinFrameSize // StackAlign is the required alignment of the SP register. // The stack must be at least word aligned, but some architectures require more.
Registered: Wed Jun 12 16:32:35 UTC 2024 - Last Modified: Tue May 17 19:48:21 UTC 2022 - 2.1K bytes - Viewed (0) -
src/runtime/memclr_mips64x.s
VMOVB W0, -48(R4) VMOVB W0, -32(R4) VMOVB W0, -16(R4) JMP done no_msa: // if less than 8 bytes, do one byte at a time SGTU $8, R2, R3 BNE R3, out // do one byte at a time until 8-aligned AND $7, R1, R3 BEQ R3, words MOVB R0, (R1) ADDV $1, R1 JMP -4(PC) words: // do 8 bytes at a time if there is room ADDV $-7, R4, R2 SGTU R2, R1, R3 BEQ R3, out MOVV R0, (R1)
Registered: Wed Jun 12 16:32:35 UTC 2024 - Last Modified: Sat Nov 06 10:24:44 UTC 2021 - 1.7K bytes - Viewed (0) -
src/vendor/golang.org/x/net/route/sys_darwin.go
ifmam2 := &wireFormat{extOff: sizeofIfmaMsghdr2Darwin15, bodyOff: sizeofIfmaMsghdr2Darwin15} ifmam2.parse = ifmam2.parseInterfaceMulticastAddrMessage // Darwin kernels require 32-bit aligned access to routing facilities. return 4, map[int]*wireFormat{ syscall.RTM_ADD: rtm, syscall.RTM_DELETE: rtm, syscall.RTM_CHANGE: rtm, syscall.RTM_GET: rtm, syscall.RTM_LOSING: rtm,
Registered: Wed Jun 12 16:32:35 UTC 2024 - Last Modified: Fri Aug 05 19:54:32 UTC 2022 - 2.8K bytes - Viewed (0)