- Sort Score
- Result 10 results
- Languages All
Results 71 - 80 of 172 for alignUp (0.79 sec)
-
tensorflow/compiler/aot/codegen_test_h.golden
// ((unknown): f32[1,2], (unknown): s64[3,4], (unknown): f32[1], (unknown): f32[1], (unknown): s32[5]) -> (u32[5,6], f32[1], s32[5]) // // Memory stats: // arg bytes total: 392 // arg bytes aligned: 576 // temp bytes total: 171 // temp bytes aligned: 512 class MyClass final : public tensorflow::XlaCompiledCpuFunction { public: // Number of input arguments for the compiled computation. static constexpr size_t kNumArgs = 5;
Registered: Sun Jun 16 05:45:23 UTC 2024 - Last Modified: Thu May 02 01:20:01 UTC 2024 - 16.6K bytes - Viewed (0) -
maven-core/src/main/java/org/apache/maven/plugin/PluginParameterExpressionEvaluatorV4.java
} else if (file.getPath().startsWith(File.separator)) { // drive-relative Windows path, don't align with project directory but with drive root file = file.getAbsoluteFile(); } else { // an ordinary relative path, align with project directory file = basedir.resolve(file.getPath()) .normalize()
Registered: Wed Jun 12 09:55:16 UTC 2024 - Last Modified: Tue Jan 30 23:39:19 UTC 2024 - 9.8K bytes - Viewed (0) -
src/cmd/link/internal/loader/symbolbuilder.go
func (sb *SymbolBuilder) SetExternal(v bool) { sb.l.SetAttrExternal(sb.symIdx, v) } func (sb *SymbolBuilder) SetValue(v int64) { sb.l.SetSymValue(sb.symIdx, v) } func (sb *SymbolBuilder) SetAlign(align int32) { sb.l.SetSymAlign(sb.symIdx, align) } func (sb *SymbolBuilder) SetLocalentry(value uint8) { sb.l.SetSymLocalentry(sb.symIdx, value) } func (sb *SymbolBuilder) SetExtname(value string) { sb.l.SetSymExtname(sb.symIdx, value) }
Registered: Wed Jun 12 16:32:35 UTC 2024 - Last Modified: Wed Nov 08 15:25:19 UTC 2023 - 13.9K bytes - Viewed (0) -
src/runtime/race_amd64.s
// Arguments are passed in DI, SI, DX, CX, R8, R9, the rest is on stack. // Callee-saved registers are: BX, BP, R12-R15. // SP must be 16-byte aligned. // On Windows: // Arguments are passed in CX, DX, R8, R9, the rest is on stack. // Callee-saved registers are: BX, BP, DI, SI, R12-R15. // SP must be 16-byte aligned. Windows also requires "stack-backing" for the 4 register arguments: // https://learn.microsoft.com/en-us/cpp/build/x64-calling-convention
Registered: Wed Jun 12 16:32:35 UTC 2024 - Last Modified: Fri May 17 18:37:29 UTC 2024 - 15.1K bytes - Viewed (0) -
src/cmd/vendor/github.com/google/pprof/internal/binutils/binutils.go
// we don't want to do it every time. But if _stext happens to be // page-aligned but isn't the same as Vaddr, we would symbolize // wrong. So if the name the addresses aren't page aligned, or if // the name is "vmlinux" we read _stext. We can be wrong if: (1) // someone passes a kernel path that doesn't contain "vmlinux" AND // (2) _stext is page-aligned AND (3) _stext is not at Vaddr symbols, err := ef.Symbols()
Registered: Wed Jun 12 16:32:35 UTC 2024 - Last Modified: Fri May 31 19:48:28 UTC 2024 - 22.3K bytes - Viewed (0) -
pkg/kubelet/cm/cpumanager/topology_hints_test.go
expectedHints []topologymanager.TopologyHint }{ { // CPU available on numa node[0 ,1]. CPU on numa node 0 can satisfy request of 2 CPU's description: "AlignBySocket:false, Preferred hints does not contains socket aligned hints", pod: *testPod1, container: *testContainer1, defaultCPUSet: cpuset.New(2, 3, 11), topology: topoDualSocketMultiNumaPerSocketHT,
Registered: Sat Jun 15 01:39:40 UTC 2024 - Last Modified: Wed Apr 24 18:25:29 UTC 2024 - 19K bytes - Viewed (0) -
src/runtime/asm_s390x.s
MOVD g, R2 // arg 0: G // C functions expect 160 bytes of space on caller stack frame // and an 8-byte aligned stack pointer MOVD R15, R9 // save current stack (R9 is preserved in the Linux ABI) SUB $160, R15 // reserve 160 bytes MOVD $~7, R6 AND R6, R15 // 8-byte align BL R11 // this call clobbers volatile registers according to Linux ABI (R0-R5, R14) MOVD R9, R15 // restore stack
Registered: Wed Jun 12 16:32:35 UTC 2024 - Last Modified: Thu Jan 25 09:18:28 UTC 2024 - 28.1K bytes - Viewed (0) -
src/runtime/race_ppc64le.s
// Third, in long-term it will allow to remove cyclic runtime/race dependency on cmd/go. // A brief recap of the ppc64le calling convention. // Arguments are passed in R3, R4, R5 ... // SP must be 16-byte aligned. // Note that for ppc64x, LLVM follows the standard ABI and // expects arguments in registers, so these functions move // the arguments from storage to the registers expected // by the ABI.
Registered: Wed Jun 12 16:32:35 UTC 2024 - Last Modified: Fri May 17 18:37:29 UTC 2024 - 17K bytes - Viewed (0) -
src/cmd/trace/tasks.go
} table#reqs tr.first { font-weight: bold; } table#reqs td { font-family: monospace; } table#reqs td.when { text-align: right; white-space: nowrap; } table#reqs td.elapsed { padding: 0 0.5em; text-align: right; white-space: pre; width: 10em; } address { font-size: smaller; margin-top: 5em; } </style> <body>
Registered: Wed Jun 12 16:32:35 UTC 2024 - Last Modified: Fri May 17 18:48:18 UTC 2024 - 11.8K bytes - Viewed (0) -
platforms/software/dependency-management/src/integTest/groovy/org/gradle/integtests/resolve/capabilities/CapabilitiesRulesIntegrationTest.groovy
Registered: Wed Jun 12 18:38:38 UTC 2024 - Last Modified: Tue Oct 10 21:10:11 UTC 2023 - 17.1K bytes - Viewed (0)