- Sort Score
- Result 10 results
- Languages All
Results 1 - 7 of 7 for failovers (0.09 sec)
-
cmd/erasure-coding.go
for _, conf := range testConfigs { failOnErr := func(err error) { if err != nil { logger.Fatal(errSelfTestFailure, "%v: error on self-test [d:%d,p:%d]: %v. Unsafe to start server.\n", algo, conf[0], conf[1], err) } } e, err := NewErasure(context.Background(), int(conf[0]), int(conf[1]), blockSizeV2) failOnErr(err) encoded, err := e.EncodeData(GlobalContext, testData[:])
Registered: Sun Nov 03 19:28:11 UTC 2024 - Last Modified: Wed Jan 31 02:11:45 UTC 2024 - 8.6K bytes - Viewed (0) -
cmd/xl-storage-format-v2_test.go
NumVersions: 1, SuccessorModTime: time.Time{}, } failOnErr(xl.AddVersion(fi)) fi.VersionID = mustGetUUID() fi.DataDir = mustGetUUID() fi.Data = data2 failOnErr(xl.AddVersion(fi)) serialized, err := xl.AppendTo(nil) failOnErr(err) // Roundtrip data var xl2 xlMetaV2 failOnErr(xl2.Load(serialized)) // We should have one data entry list, err := xl2.data.list()
Registered: Sun Nov 03 19:28:11 UTC 2024 - Last Modified: Fri Mar 08 17:50:48 UTC 2024 - 36.4K bytes - Viewed (0) -
docs/features/calls.md
Calls are executed in one of two ways: * **Synchronous:** your thread blocks until the response is readable.
Registered: Fri Nov 01 11:42:11 UTC 2024 - Last Modified: Sun Feb 06 02:19:09 UTC 2022 - 3.9K bytes - Viewed (0) -
src/main/java/jcifs/Configuration.java
*/ boolean isRequireSecureNegotiate (); /** * Enable port 139 failover * * Property <tt>jcifs.smb.client.port139.enabled</tt> (boolean, default false) * * @return whether to failover to legacy transport on port 139 */ boolean isPort139FailoverEnabled (); /** *
Registered: Sun Nov 03 00:10:13 UTC 2024 - Last Modified: Thu Jan 05 13:06:39 UTC 2023 - 18K bytes - Viewed (0) -
cmd/object-api-utils.go
data[i] = byte(rng.Int63() & 3) } failOnErr := func(err error) { if err != nil { logger.Fatal(errSelfTestFailure, "compress: error on self-test: %v", err) } } const skip = 2<<20 + 511 r, _ := newS2CompressReader(bytes.NewBuffer(data), int64(len(data)), true) b, err := io.ReadAll(r) failOnErr(err) failOnErr(r.Close()) // Decompression reader.
Registered: Sun Nov 03 19:28:11 UTC 2024 - Last Modified: Thu Aug 08 15:29:58 UTC 2024 - 37.1K bytes - Viewed (0) -
docs/bucket/replication/DESIGN.md
requires a setting in the replication configuration called [replica modification sync](https://aws.amazon.com/about-aws/whats-new/2020/12/amazon-s3-replication-adds-support-two-way-replication/). For active-active replication, automatic failover occurs on `GET/HEAD` operations if object or object version requested qualifies for replication and is missing on one site, but present on the other. This allows the applications to take full advantage of two-way replication even before the two sites...
Registered: Sun Nov 03 19:28:11 UTC 2024 - Last Modified: Thu Sep 29 04:28:45 UTC 2022 - 14.7K bytes - Viewed (0) -
CHANGELOG/CHANGELOG-1.24.md
- Non-graceful node shutdown handling is enabled for stateful workload failovers ([#108486](https://github.com/kubernetes/kubernetes/pull/108486), [@sonasingh46](https://github.com/sonasingh46))
Registered: Fri Nov 01 09:05:11 UTC 2024 - Last Modified: Thu Aug 24 00:02:43 UTC 2023 - 473.4K bytes - Viewed (0)