Search Options

Results per page
Sort
Preferred Languages
Advance

Results 1 - 5 of 5 for previous (0.16 sec)

  1. docs/tls/kubernetes/README.md

    ```
    
    Note that the `secretName` should be same as the secret name created in previous step. Then add the below section under
    `spec.containers[].volumeMounts[]`
    
    ```yaml
        volumeMounts:
            - name: secret-volume
              mountPath: /<user-running-minio>/.minio/certs
    ```
    
    Here the name of `volumeMount` should match the name of `volume` created previously. Also `mountPath` must be set to the path of
    Plain Text
    - Registered: Sun May 05 19:28:20 GMT 2024
    - Last Modified: Thu Sep 29 04:28:45 GMT 2022
    - 3K bytes
    - Viewed (0)
  2. docs/erasure/storage-class/README.md

    ### Set metadata
    
    In below example `minio-go` is used to set the storage class to `REDUCED_REDUNDANCY`. This means this object will be split across 6 data drives and 2 parity drives (as per the storage class set in previous step).
    
    ```go
    s3Client, err := minio.New("localhost:9000", "YOUR-ACCESSKEYID", "YOUR-SECRETACCESSKEY", true)
    if err != nil {
     log.Fatalln(err)
    }
    
    object, err := os.Open("my-testfile")
    if err != nil {
    Plain Text
    - Registered: Sun May 05 19:28:20 GMT 2024
    - Last Modified: Tue Aug 15 23:04:20 GMT 2023
    - 5.8K bytes
    - Viewed (1)
  3. docs/sts/README.md

    - [Configuring etcd](https://github.com/minio/minio/blob/master/docs/sts/etcd.md)
    
    ### Setup MinIO with Identity Provider
    
    Make sure we have followed the previous step and configured each software independently, once done we can now proceed to use MinIO STS API and MinIO server to use these credentials to perform object API operations.
    
    #### KeyCloak
    
    ```
    export MINIO_ROOT_USER=minio
    Plain Text
    - Registered: Sun May 05 19:28:20 GMT 2024
    - Last Modified: Tue Oct 25 00:44:15 GMT 2022
    - 7.8K bytes
    - Viewed (1)
  4. docs/site-replication/README.md

    ```sh
    mc admin replicate add minio1 minio2 minio3
    ```
    
    - Once the above command returns success, you may query site replication configuration with:
    
    ```sh
    mc admin replicate info minio1
    ```
    
    ** Note **
    Plain Text
    - Registered: Sun May 05 19:28:20 GMT 2024
    - Last Modified: Mon Feb 26 21:30:28 GMT 2024
    - 3.4K bytes
    - Viewed (0)
  5. docs/integrations/veeam/README.md

    - Under Home > Jobs > Backup in Navigation Pane, click on Backup Job button in the ribbon and choose Virtual Machine. Follow the on screen wizard.
    
    - On the Storage screen, choose the Scale-out Backup Repository that was configured previously.
    
    Plain Text
    - Registered: Sun May 05 19:28:20 GMT 2024
    - Last Modified: Thu Sep 29 04:28:45 GMT 2022
    - 5.4K bytes
    - Viewed (0)
Back to top